On a vessel 36 feet (11.8 meters) or more in length, a visual and audible alarm must be provided at the operating station to indicate high water level in each of the following normally unmanned spaces:

§ 28.250 § 28.250 High water alarms. On a vessel 36 feet (11.8 meters) or more in length, a visual and audible alarm must be provided at the operating station to indicate high water level in each of the following normally unmanned spaces:

(a)A space with a through-hull fitting below the deepest load waterline, such as the lazarette;

(b)A machinery space bilge, bilge well, shaft alley bilge, or other space subject to flooding from sea water piping within the space; and

(c)A space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck.