(a) For the purpose of this subpart, an industrial system is a system that—

Section 111.107-1 — full text

Rendered cleanly from the source — the exact regulatory text, with subsection structure preserved.

(a)For the purpose of this subpart, an industrial system is a system that—

(1)Is not a ship's service load, as defined in § 110.15-1;

(2)Is used only for the industrial function of the vessel;

(3)Is not connected to the emergency power source; and

(4)Does not have specific requirements addressed elsewhere in this subchapter.

(b)An industrial system that meets the applicable requirements of NFPA 70 (incorporated by reference; see § 110.10-1 of this subchapter) must meet only the following:

(1)Part 110, subpart 110.25, of this chapter—Plan Submittal.

(2)Subpart 111.01 of this part—General.

(3)Subpart 111.05 of this part—Equipment Ground, Ground Detection, and Grounded Systems.

(4)Sections 111.12-1(b) and 111.12-1(c)—Prime movers.

(5)Sections 111.30-1, 111.30-5(a), and 111.30-19(a)—Switchgear.

(6)Subpart 111.105 of this part—Hazardous Locations.

(c)Cables that penetrate a watertight or fire boundary deck or bulkhead must—

(1)Be installed in accordance with 46 CFR 111.60-5 and meet the flammability-test requirements of either IEEE 1202, IEC 60332-3-22:2018, or IEC 60332-3-21:2018, Category A or A F/R (all incorporated by reference; see § 110.10-1 of this subchapter); or

(2)Be specialty cable installed in accordance with § 111.60-2. [CGD 94-108, 61 FR 28286, June 4, 1996, as amended at 62 FR 23910, May 1, 1997; USCG-2003-16630, 73 FR 65201, Oct. 31, 2008; USCG-2020-0075, 88 FR 16368, Mar. 16, 2023]

From regulation to exam

See how this section shows up on the test

Test your knowledge

Try 5 real exam questions on the rules behind this regulation — no sign-up needed.

Was this page helpful?

Start drilling in 30 seconds. Free.

No signup, no credit card — answer 5 real, cited exam questions right now.

46 CFR §111.107-1 — -1 -1 Industrial systems · CaptainsGround