Each cable entering a box or fitting must be protected from abrasion and must meet the following:

Section 111.81-3 — full text

Rendered cleanly from the source — the exact regulatory text, with subsection structure preserved.

Each cable entering a box or fitting must be protected from abrasion and must meet the following:

(a)Each opening through which a conductor enters must be closed.

(b)Cable armor must be secured to the box or fitting.

(c)Each cable entrance in a damp or wet location must be made watertight by a terminal or stuffing tube.

(a)Each opening through which a conductor enters must be closed.

(b)Cable armor must be secured to the box or fitting.

(c)Each cable entrance in a damp or wet location must be made watertight by a terminal or stuffing tube.