(a) Except as otherwise provided in this paragraph, all engine exhaust pipes must be water cooled.

Section 182.425 — full text

Rendered cleanly from the source — the exact regulatory text, with subsection structure preserved.

(a)Except as otherwise provided in this paragraph, all engine exhaust pipes must be water cooled.

(1)Vertical dry exhaust pipes are permissible if installed in compliance with §§ 177.405(b) and 177.970 of this chapter.

(2)Horizontal dry exhaust pipes are permitted only if:

(i)They do not pass through living or berthing spaces;

(ii)They terminate above the deepest load waterline;

(iii)They are so arranged as to prevent entry of cold water from rough or boarding seas;

(iv)They are constructed of corrosion resisting material at the hull penetration; and

(v)They are installed in compliance with §§ 177.405(b) and 177.970 of this chapter.

(b)The exhaust pipe cooling water system must comply with the requirements of this paragraph.

(1)Water for cooling the exhaust pipe must be obtained from the engine cooling water system or a separate engine driven pump.

(2)Water for cooling the exhaust pipe, other than a vertical exhaust, must be injected into the exhaust system as near to the engine manifold as practicable. The water must pass through the entire length of the exhaust pipe.

(3)The part of the exhaust system between the point of cooling water injection and the engine manifold must be water-jacketed or effectively insulated and protected in compliance with §§ 177.405(b) and 177.970 of this chapter.

(4)Vertical exhaust pipes must be water-jacketed or suitably insulated as required by § 182.430(g).

(5)When the exhaust cooling water system is separate from the engine cooling water system, a suitable warning device, visual or audible, must be installed at the operating station to indicate any reduction in normal water flow in the exhaust cooling system.

(6)A suitable hull strainer must be installed in the circulating raw water intake line for the exhaust cooling system.

(c)Engine exhaust cooling system built in accordance with the requirements of ABYC P-1 (incorporated by reference; see 46 CFR 175.600) will be considered as meeting the requirements of this section. [CGD 85-080, 61 FR 986, Jan. 10, 1996; 61 FR 20557, May 7, 1996, as amended by USCG-2003-16630, 73 FR 65207, Oct. 31, 2008]

From regulation to exam

See how this section shows up on the test

Test your knowledge

Try 5 real exam questions on the rules behind this regulation — no sign-up needed.

Start drilling in 30 seconds. Free.

No signup, no credit card — answer 5 real, cited exam questions right now.

46 CFR §182.425 — Engine exhaust cooling · CaptainsGround