USCG Exam Practice · Abandon ship procedures and life rafts
Under 46 CFR §199.150, a launching appliance for survival craft must be capable of launching the fully equipped survival craft under what maximum conditions of trim and list?
- ATrim of up to 5 degrees either way and list of up to 15 degrees either way
- BTrim of up to 10 degrees either way and list of up to 20 degrees either way✓ correct
- CTrim of up to 15 degrees either way and list of up to 20 degrees either way
- DTrim of up to 10 degrees either way and list of up to 30 degrees either way
Why B is correct
46 CFR §199.150(c) requires each launching appliance to be arranged so that the fully equipped survival craft can be safely launched against unfavorable conditions of trim of up to 10 degrees either way and list of up to 20 degrees either way, both with full complement and with operating crew only.
Cited:46 CFR §199.150