Skip to main content
CaptainsGround
Every answer cited & verifiedAll 4 USCG exam modulesReviewed by a former NMC exam writer
USCG Exam PracticePumps, valves, and piping systems

According to 46 CFR Part 56, which of the following piping systems installed on a mobile offshore drilling unit is NOT required to fully comply with Part 56?

  1. A. Bilge and ballast piping
  2. Industrial systems pipingCorrect
  3. C. Fire main piping
  4. D. Fuel oil service piping

Why B is correct

46 CFR §56.01-1(c) states that piping for industrial systems on mobile offshore drilling units need not fully comply with Part 56, but must instead meet subpart 58.60. Bilge, fire main, and fuel oil service piping are all subject to full Part 56 compliance.