According to 46 CFR §183.530, electrical equipment installed in a space containing fuel tanks for gasoline must be which of the following?

  1. A. Weatherproof and double-insulated
  2. Explosion-proof, ignition-protected, or part of an intrinsically safe systemCorrect
  3. C. Grounded to the vessel's hull and fused at 15 amperes or less
  4. D. Rated for Class II, Division 1 locations per NFPA 70

Why B is correct

46 CFR §183.530(a) requires that electrical equipment in spaces containing machinery powered by, or fuel tanks for, gasoline or other fuels with a flashpoint of 43.3 °C (110 °F) or lower must be explosion-proof, ignition-protected, or part of an intrinsically safe system. Weatherproof or double-insulated ratings are not listed as acceptable alternatives.