Skip to main content
CaptainsGround
Every answer cited & verifiedAll 4 USCG exam modulesReviewed by a former NMC exam writer
USCG Exam PracticeLube oil and fuel oil systems

Under 46 CFR §56.50-60, each drain from a heating coil installed in an oil tank must discharge to which location?

  1. An inspection tank or other suitable oil detectorCorrect
  2. B. The vessel's bilge through a drip pan
  3. C. The fuel oil settling tank
  4. D. Directly overboard through a monitored discharge

Why A is correct

46 CFR §56.50-60(b)(1) requires that each drain from a heating coil, as well as each drain from an oil heater, must run to an inspection tank or other suitable oil detector. Discharging to the bilge is specifically prohibited by §56.50-60(k), which requires drip pans to prevent oil from reaching the bilge.

More Lube oil and fuel oil systems questions

Start drilling in 30 seconds. Free.

No signup, no credit card — answer 5 real, cited exam questions right now.

Under 46 CFR §56.50-60, each drain from a heating coil installed in… — USCG Exam Practice · CaptainsGround