Under 46 CFR §111.51-3, for an AC system with aggregate generating capacity below 1500 kW, what is the assumed maximum asymmetrical short-circuit current?
- A. 8 times aggregate rated generator currents plus 3 times aggregate rated motor currents.
- B. 10 times aggregate rated generator currents plus 6 times aggregate rated motor currents.
- ✓ 10 times aggregate rated generator currents plus 4 times aggregate rated motor currents.Correct
- D. 8 times aggregate rated generator currents plus 4 times aggregate rated motor currents.
Why C is correct
46 CFR §111.51-3(b) specifies that the maximum asymmetrical short-circuit current for an AC system is 10 times the aggregate normal rated generator currents plus 4 times the aggregate normal rated currents of all motors that may be in operation. Option A is the average asymmetrical value per §111.51-3(c); option B applies to DC systems per §111.51-3(a).
Cited:46 CFR §111.51-3