Under 46 CFR §63.01-3, an automatic auxiliary boiler with a heat input rating of 14,000,000 Btu/hr must have its automatic control system regulated under which part of Title 46?

  1. A. Part 63, because it is an automatic auxiliary boiler regardless of heat input
  2. Part 52 for the boiler and Part 62 for the control system, because the heat input rating equals or exceeds 12,500,000 Btu/hrCorrect
  3. C. Part 56 for the piping and Part 63 for the controls
  4. D. Part 63 for the boiler and Part 56 for the external piping only

Why B is correct

46 CFR §63.01-3(b) states that automatic boilers with heat input ratings of 12,500,000 Btu/hr (3.66 megawatts) and above must meet the requirements of Part 52, and their control systems must meet the requirements of Part 62. Part 63 governs automatic auxiliary boilers below that threshold.