A refrigeration compressor trips on the high-pressure cutout. Which of the following conditions is LEAST likely to be the cause?

  1. A. Fouled or scaled condenser tubes
  2. B. Loss of cooling water flow to the condenser
  3. C. Non-condensable air trapped in the condenser shell
  4. Low refrigerant charge in the systemCorrect

Why D is correct

NAVEDTRA 14075 §6-2 and §6-3 identify fouled condenser tubes, lost cooling water, and non-condensable air as causes of elevated high-side pressure that can trip the high-pressure cutout. A low refrigerant charge reduces suction pressure and would more likely trip the low-pressure cutout, not the high-pressure cutout.