According to 46 CFR §183.220, an electrical enclosure that contains more than one source of power must be fitted with which of the following?

  1. A. A ground fault circuit interrupter on each circuit
  2. A sign warning of multiple power sources and identifying the circuits to be disconnectedCorrect
  3. C. A separate watertight cover for each power source
  4. D. An intrinsically safe isolation switch rated for the total combined load

Why B is correct

46 CFR §183.220(e) requires that any cabinet, panel, box, or other enclosure containing more than one source of power be fitted with a sign warning persons of this condition and identifying the circuits to be disconnected. This is a personnel safety measure to prevent inadvertent energization during maintenance.