Skip to main content
CaptainsGround
Every answer cited & verifiedAll 4 USCG exam modulesReviewed by a former NMC exam writer
USCG Exam PracticeMotors and generators

A shipboard DC series motor driving a cargo hoist is accidentally uncoupled from its load while running. What is the immediate danger?

  1. A. The motor will stall due to excessive counter-EMF with no load current
  2. B. The motor will reverse direction because the series field collapses
  3. The motor will accelerate uncontrollably to a dangerously high speedCorrect
  4. D. The motor will draw reduced current and overheat the shunt field winding

Why C is correct

NEETS Mod. 5 §2-2 states that a series DC motor must never be run without a mechanical load because unloaded it accelerates uncontrollably. For this reason, series motors are belted or geared directly to their loads rather than coupled through a clutch that could release.

More Motors and generators questions

Start drilling in 30 seconds. Free.

No signup, no credit card — answer 5 real, cited exam questions right now.

A shipboard DC series motor driving a cargo hoist is accidentally u… — USCG Exam Practice · CaptainsGround