Under 46 CFR §111.05-17, the neutral of an emergency power generation system must be grounded in which manner?

  1. A. With a direct ground connection at the emergency switchboard and no connection to the main switchboard neutral bus
  2. With no direct ground at the emergency switchboard, the neutral bus permanently connected to the main switchboard neutral bus, and no switch, breaker, or fuse in the bus-tie neutral conductorCorrect
  3. C. With a direct ground at the emergency switchboard and a fused connection to the main switchboard neutral bus
  4. D. With no direct ground at the emergency switchboard and a circuit breaker in the bus-tie neutral conductor to allow isolation during testing

Why B is correct

46 CFR §111.05-17(a)(1)-(3) sets three simultaneous requirements for the emergency system neutral: no direct ground at the emergency switchboard, permanent connection of the neutral bus to the main switchboard neutral bus, and no switch, circuit breaker, or fuse in the bus-tie neutral conductor.