Under 46 CFR §111.70-1, the motor disconnecting means on a vessel must be which of the following?

  1. An externally operable switch or circuit breakerCorrect
  2. B. An internally mounted fuse block accessible only with tools
  3. C. A remote-operated contactor controlled from the bridge
  4. D. A thermal overload relay with manual reset

Why A is correct

46 CFR §111.70-1(c) states explicitly that the motor disconnecting means must be an externally operable switch or circuit breaker. A thermal overload relay provides running protection, not disconnection, and a fuse block or remote contactor does not satisfy the externally operable requirement.