In an ungrounded three-phase AC system aboard a vessel, how many motor-running protective devices are required, and in which conductors must they be placed?

  1. A. Three devices, one in each ungrounded conductor
  2. Two devices, in any two ungrounded conductorsCorrect
  3. C. Two devices, one in an ungrounded conductor and one in the grounded neutral
  4. D. Three devices, one in each phase plus one in the neutral

Why B is correct

46 CFR §111.70-1(b) states that in ungrounded three-phase AC systems, only two motor-running protective devices need be used, placed in any two ungrounded conductors. The exception applies when a wye-delta or delta-wye transformer is used.