Under 46 CFR §111.95-3, what restriction applies to a main line emergency disconnect switch that is accessible to unauthorized persons?

  1. A. It must be fitted with a key-operated rotary switch that locks in both the open and closed positions
  2. It must have a means to lock the switch in the open-circuit position, and must not lock in the closed-circuit positionCorrect
  3. C. It must be enclosed in a locked cabinet and operable only by a licensed engineer
  4. D. It must be fitted with an alarm that sounds whenever the switch is operated

Why B is correct

46 CFR §111.95-3(b) requires that each main line emergency disconnect switch accessible to an unauthorized person have a means to lock the switch in the open-circuit position with a padlock or equivalent, and explicitly states the switch must not lock in the closed-circuit position.