Under 46 CFR §111.15-5, a moderate battery installation located in a ventilated engineroom and protected from falling objects requires which of the following?

  1. A. A dedicated battery room with hazardous-location electrical equipment
  2. B. A box or locker within the engineroom
  3. No enclosing box or lockerCorrect
  4. D. Relocation to a box on deck

Why C is correct

46 CFR §111.15-5(b) states that if a moderate battery installation is in a ventilated compartment such as the engineroom and is protected from falling objects, a box or locker is not required. The dedicated room and hazardous-location equipment requirements apply to large installations.