USCG Exam Practice · Fire extinguishers — types, ratings, requirements
A recreational vessel of 350 gross tons and more than 65 feet in length does NOT have a fixed fire extinguishing system in the machinery space. Which additional fire extinguishing equipment is required in the machinery space beyond the portable extinguishers mandated by gross tonnage?
- AOne 160-B semi-portable fire extinguishing system permanently attached to a bulkhead or deck✓ correct
- BTwo 20-B portable extinguishers regardless of engine horsepower
- COne 20-B extinguisher per 1,000 BHP only; no semi-portable system is required below 500 gross tons
- DA fixed CO2 system designed per 46 CFR part 76, subpart 76.15, is mandatory at this tonnage
Why A is correct
33 CFR §175.320(b)(2)(ii) requires that on recreational vessels of more than 300 gross tons, either one 160-B semi-portable fire extinguishing system must be fitted or a fixed fire extinguishing system must be fitted in the machinery space. Since no fixed system is installed, the 160-B semi-portable is required. Per §175.320(b)(3), its frame must be welded or otherwise permanently attached to a bulkhead or deck.
Cited:33 CFR §175.320
Drill more Fire extinguishers — types, ratings, requirements questions
Every CaptainsGround answer cites the rule it tests — verified, not guessed. Try a free 5-question drill, no sign-up.
More practice questions
- Under 33 CFR §175.310, which of the following conditions indicates that a portable fire…
- Which type of portable fire extinguisher agent is expressly prohibited from being used …
- A recreational vessel more than 65 feet in length has main engines producing a combined…
- A recreational vessel 30 feet in length has no fixed fire extinguishing system in the m…
- Under 33 CFR §175.310, which of the following conditions renders a portable fire exting…