According to 46 CFR §28.380, where insulation of any type is used in a machinery space or paint locker, what additional protective measure is required?

  1. A. The insulation must be noncombustible in all cases
  2. A vapor barrier covering the insulation must be providedCorrect
  3. C. The insulation must be removed and replaced with steel lagging
  4. D. A fixed fire detection system must be installed adjacent to the insulation

Why B is correct

46 CFR §28.380(f) requires that where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present — such as machinery spaces and paint lockers — a vapor barrier covering the insulation must be provided. This applies regardless of whether the insulation itself is combustible or noncombustible.