Under 46 CFR §111.106-3(j), which of the following arrangements for cargo pumping and piping systems is required?

  1. A. Cargo transfer pumps may pass through machinery spaces provided they are enclosed in cofferdams
  2. Cargo pumping and piping systems must be arranged independently from all other systems and must not be located in or pass through accommodation, service, or machinery spacesCorrect
  3. C. Sounding piping may pass through accommodation spaces if it is enclosed in a vapor-tight conduit
  4. D. Fill and discharge piping may share a common manifold with ballast systems provided the systems are valved off when not in use

Why B is correct

46 CFR §111.106-3(j) requires that cargo pumping and piping systems be arranged independently from all other systems, and that cargo transfer pumps and piping — including fill, discharge, vent, and sounding piping — must not be located in or pass through any accommodation, service, or machinery spaces. No exceptions for cofferdams, vapor-tight conduits, or shared manifolds are provided in this paragraph.