Skip to main content
CaptainsGround
Every answer cited & verifiedAll 4 USCG exam modulesReviewed by a former NMC exam writer
USCG Exam PracticeLube oil and fuel oil systems

Under 46 CFR, what is the minimum number of fuel oil service pumps required on a vessel with oil-fired main boilers, and what capacity must each pump have?

  1. A. One pump of sufficient capacity to supply all boilers at full power.
  2. Two pumps, each of sufficient capacity to supply all boilers at full power.Correct
  3. C. Two pumps whose combined capacity is sufficient to supply all boilers at full power.
  4. D. Three pumps, with two in service and one on standby at all times.

Why B is correct

46 CFR §56.50-65(b)(1) requires all vessels with oil-fired boilers to have at least two fuel service pumps, each of sufficient capacity to supply all boilers at full power, arranged so that one may be overhauled while the other remains in service. A single pump or a combined-capacity arrangement does not satisfy this requirement.

More Lube oil and fuel oil systems questions

Start drilling in 30 seconds. Free.

No signup, no credit card — answer 5 real, cited exam questions right now.

Under 46 CFR, what is the minimum number of fuel oil service pumps… — USCG Exam Practice · CaptainsGround