A compartment located entirely below the weather deck contains gas-consuming appliances. What ventilation is required by regulation?

  1. A. At least two natural ventilator ducts, one extending to the floor and one to the overhead
  2. Powered ventilation sufficient to change the air at least once every 6 minutes, with the motor located outside the compartmentCorrect
  3. C. Powered ventilation sufficient to change the air at least once every 10 minutes, with the motor located inside the compartment
  4. D. Natural ventilation with a minimum of one duct extending to the floor level

Why B is correct

46 CFR §58.16-20(b) requires powered ventilation of sufficient capacity to effect a change of air at least once every 6 minutes for compartments below the weather deck containing gas-consuming appliances, and the motor must be located outside the compartment.