According to federal regulations, a compartment located entirely below the weather deck that contains gas-consuming appliances must be provided with powered ventilation capable of changing the air at least once every ___.

  1. A. 3 minutes
  2. 6 minutesCorrect
  3. C. 10 minutes
  4. D. 15 minutes

Why B is correct

46 CFR §58.16-20(b) requires powered ventilation sufficient to effect a change of air at least once every 6 minutes for below-deck compartments containing gas-consuming appliances. The motor for that ventilation must be located outside the compartment.