Skip to main content
CaptainsGround

USCG Exam Practice · Vessel stability — metacentric height, free surface

Under 46 CFR §28.570, what is the minimum initial metacentric height (GM) required for a commercial fishing vessel in each condition of loading?

  1. A0.66 feet (0.2 meters)
  2. B1.15 feet (0.35 meters)✓ correct
  3. C1.50 feet (0.46 meters)
  4. D0.35 feet (0.11 meters)

Why B is correct

46 CFR §28.570(a)(1) specifies a minimum initial GM of 1.15 feet (0.35 meters) in each condition of loading. Option A is the minimum righting arm (GZ) value at 30°, not the GM requirement.

Drill more Vessel stability — metacentric height, free surface questions

Every CaptainsGround answer cites the rule it tests — verified, not guessed. Try a free 5-question drill, no sign-up.

More practice questions

Under 46 CFR §28.570, what is the minimum initial metacentric heigh… — USCG Exam Practice · CaptainsGround