According to 46 CFR §28.335, each integral fuel tank vent pipe on a commercial fishing vessel must terminate in what configuration on the weather deck?

  1. A. A 90-degree bend fitted with a flame screen
  2. A 180-degree bend fitted with a flame screenCorrect
  3. C. A straight open pipe fitted with a check valve
  4. D. A 180-degree bend fitted with a pressure-relief valve

Why B is correct

46 CFR §28.335(d)(1) requires each integral fuel tank vent pipe to be connected to the highest point of the tank, terminate in a 180-degree bend on a weather deck, and be fitted with a flame screen. A 90-degree bend or check valve does not satisfy this requirement.

More Fueling procedures and pollution prevention questions