Under 46 CFR §28.835, supply piping that conveys fuel oil to equipment in close proximity to lines or equipment with parts operating above 260 °C (500 °F) must be constructed of which material?

  1. A. Annealed seamless copper with a minimum wall thickness of 0.9 mm
  2. B. Brass or nickel-copper alloy tubing
  3. Seamless steelCorrect
  4. D. Nonmetallic flexible hose reinforced with wire braid

Why C is correct

46 CFR §28.835(k) specifically requires supply piping conveying fuel oil or lubricating oil in close proximity to equipment or lines with an open flame or parts operating above 260 °C (500 °F) to be of seamless steel. The other metallic and nonmetallic options permitted elsewhere in §28.835 do not satisfy this elevated-temperature proximity requirement.