Under 46 CFR §111.106-3, lighting circuits serving explosion-proof or flameproof fixtures in an enclosed hazardous space must meet several requirements. Which of the following is specifically required?

  1. A. The switch and overcurrent device must be located inside the space for immediate access
  2. B. A single lighting branch circuit is sufficient provided it is rated for the full connected load
  3. The switch and overcurrent protective device must open all ungrounded conductors simultaneouslyCorrect
  4. D. Ground fault circuit interrupters must be installed on each branch circuit within the space

Why C is correct

46 CFR §111.106-3(e)(4) requires that the switch and overcurrent protective device for lighting circuits in enclosed hazardous spaces must open all ungrounded conductors of the circuit simultaneously. Additionally, §111.106-3(e)(3) prohibits placing the switch and overcurrent device within the space, making option A incorrect.