A lube-oil cooler aboard a vessel has been in service for several months without cleaning. The lube-oil outlet temperature has risen above normal limits even though seawater flow rate and inlet temperatures are unchanged. What is the most likely cause, and what property does it affect?

  1. A. Increased seawater salinity has raised the specific heat of the cooling water, reducing heat absorption
  2. Fouling on the tube surfaces has added thermal resistance, lowering the overall heat-transfer coefficientCorrect
  3. C. Counter-flow has shifted to parallel-flow as scale accumulates at the inlet, reducing the log-mean temperature difference
  4. D. Air in-leakage has raised the partial pressure of the seawater, reducing its latent heat capacity

Why B is correct

DOE-HDBK-1018 Vol.1 §2-1 identifies fouling — scale, sludge, or oil films — as the most common reason a cooler gradually loses capacity, because it adds thermal resistance and lowers the overall heat-transfer coefficient. DOE-HDBK-1012 §2-3 confirms that anything adding resistance lowers the overall coefficient and heat transferred.