Skip to main content
CaptainsGround
Every answer cited & verifiedAll 4 USCG exam modules4,000+ judge-verified questions
USCG Exam PracticeMotors and generators

A DC generator fails to build up voltage after being restarted. Which of the following is the most likely cause?

  1. A. The armature is rotating too fast for the field poles
  2. B. The commutator segments are too numerous for the armature coils
  3. The generator has lost its residual magnetism in the field polesCorrect
  4. D. The shunt field rheostat is set to minimum resistance

Why C is correct

NEETS Mod. 5 §1-3 states that self-excited generators build up voltage from residual magnetism in the field poles, and that loss of residual magnetism is a common cause of no-output faults. Residual magnetism can be restored by briefly flashing the field from a separate DC source.

More Motors and generators questions

Start drilling in 30 seconds. Free.

No signup, no credit card — answer 5 real, cited exam questions right now.

A DC generator fails to build up voltage after being restarted. Whi… — USCG Exam Practice · CaptainsGround