Per 46 CFR §111.70-7, a conductor of a remote control circuit of a motor controller is NOT required to have overcurrent protection under which of the following conditions?

  1. The conductor is wholly within the controller enclosureCorrect
  2. B. The conductor runs between two separate motor-control centers on the same deck
  3. C. The control circuit voltage exceeds 24 volts
  4. D. The conductor carries interlock signals between two different machinery spaces

Why A is correct

46 CFR §111.70-7(a)(1) exempts conductors that are wholly within the controller enclosure from the overcurrent protection requirement. Conductors running externally between equipment do not qualify for this exemption.