Under 46 CFR §111.15-3(b), a sealed battery that generates less hydrogen than an equivalent lead-acid battery under normal charging and discharging conditions may be treated in what manner with respect to its installation category?

  1. A. It must be upgraded to the next higher installation category regardless of hydrogen output
  2. Its battery category may be reduced to an equivalent category of lead-acid batteriesCorrect
  3. C. It is exempt from all battery installation requirements in subpart 111.15
  4. D. It must be classified as a large installation to account for unknown hydrogen generation

Why B is correct

46 CFR §111.15-3(b) provides that batteries generating less hydrogen than an equivalent lead-acid battery (e.g., sealed batteries) may have their category reduced to the equivalent lead-acid category. This allows less restrictive installation requirements based on reduced hazard, not exemption from all requirements.